The article by Houser and others, ‘A Test of the S/P Ratio as a Correlate for Brightness Perception using Rapid-Sequential and Side-by-Side Experimental Protocols’ (Leukos, 6(2):119) is reviewed here with the intent of providing some understanding of why those authors have come to such different conclusions than Berman and others. We discovered that the authors have made a number of subtle, but important errors in their statistical analysis. There are also a number of misunderstandings in their application of trichromacy. Our re-analysis leads to conclusion that their data raises very interesting questions regarding brightness constancy and color effects, but does not support most of their claims regarding trichromacy.
An installation in a Federal building tested the efficacy of a
highly-controlled, workstation-specific lighting retrofit. The study took
place in 86 cubicles in an open office with low levels of daylight. A
direct/indirect pendant luminaire with three 32 watt lamps, two DALI
ballasts, and an occupancy sensor provided both task and ambient
light for each cubicle. All three lamps turned on and off according to
occupancy on a workstation-by-workstation basis. Field measurements
taken over the course of several months demonstrated 40 percent
lighting energy savings compared to a baseline that represents a
typical Federal building retrofit; the baseline has a lighting power
density of 8.9W/m2 (0.83W/ft2) and no advanced controls. A
photometric analysis found that the installation provided higher
desktop light levels than the baseline did, while an occupant survey
suggested that occupants preferred the lighting system to the baseline.
The design of buildings and their daylighting is associated
with windows and their glass light transmittance in the response with
external daylight conditions. The article presents results of a
comparative daylight simulation study focused on evaluation of
influence of different window glazings on daylighting in an open-plan
office in an administrative building. A clear window glass variation
was compared with solar control clear and tinted glass alternatives in
the simulations. Daylight study was carried out for the investigated
office with and without effect interior furniture.
In this work, two types of commercially available compact
fluorescent lamps (CFL) were investigated for intensity variation
due to mechanical vibrations in the range of 0 to 30 Hz. In
general, subjecting the lamps to 24-hour vibration affects the total
intensity. Percentage variations of peak intensities after
vibrations is in the range of + 10 to + 35 percent in case of CFL
(Nuvue), whereas for the CFL (Ecosmart), it is in the range of -10
to + 10 percent. Continuous vibration measurements at various
vibrational frequencies (intensity measurements at each frequency
after subjecting the unit to mechanical vibrations for 10 minutes)
show that the CFL luminaires, exhibits a peak in intensity at a
vibrational frequency around 25 Hz for a wavelength of 546.78
nm (wavelength of maximum human sensitivity). Intensity
variation effects due to vibration are attributed to the dropping off
loose phosphor coatings in the inside wall of the glass enclosures.
This hypothesis needs to be investigated further.